Part Number Hot Search : 
AM79C 54LS83A 2SD17 AN7190 AP1661 BC550 2SD17 813LHG
Product Description
Full Text Search
 

To Download X3PM-100KPGVR Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Pre-amplified/3V Excitation/Gauge
Features
. . . . . 3V excitation, Battery operation available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Non-corrosive liquid measurable (X3PMC, X3HMC only)
X3PM,X3HM Data sheet
Applications
. Industrial instrumentation . Pressure switch, Pneumatic device . Medical device
Part number for ordering
X3PM C - 050KP G R
Terminal leads direction(See Outline Diagram) No mark : Rated pressure (Pa) Model X3PM X3HM Available pressure media No mark : Non-corrosive gas only C : Non-corrosive gas and liquid (Contact us about availability)
Pressure type X3PM
R : Pressure type G : Gauge (Positive pressure) GV : Gauge (Negative pressure) GW : Gauge (Bipolar pressure)
Gauge pressure X3HM
Model
Package configuration Measurable pressure range (kPa) 100 100 0 100 0 50 0 100 0 200 0 1000
Dual-In-line-Package (DIP) Part number for ordering X3PM-100KPGWR X3PM-100KPGVR X3PM-050KPGR X3PM-100KPGR X3PM-200KPGR X3PM-001MPGR
Horizontal pressure port DIP
X3PM-100KPGW X3PM-100KPGV X3PM-050KPG X3PM-100KPG X3PM-200KPG X3PM-001MPG
X3HM-100KPGWR X3HM-100KPGVR X3HM-050KPGR X3HM-100KPGR X3HM-200KPGR X3HM-001MPGR
Specifications
Model/Rated pressure 100KPGW 100KPGV 050KPG 100KPG 200KPG 001MPG Unit Recommended operating conditions Pressure type Gauge pressure 100 100 50 100 200 1000 Rated pressure 1.020 1.020 0.510 1.020 2.040 10.20 Measurable pressure range 100 100 0 100 0 50 0 100 0 200 0 1000 Pressure media 1 XFPM, XFHM : Non-corrosive gas only, XFPMC, XFHMC : Non-corrosive gas and liquid Excitation voltage 3.0 0.15 Absolute maximum rating 1.5times of rated pressure Maximum load pressure Twice of rated pressure Maximum excitation voltage 6 Operating temperature 10 80 Storage temperature 20 100 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=3.0V constant, Ambient temperature Ta=25 ) Current consumption less than 6 Output impedance less than 10 Source current less than 0.1 Sink current less than 1.0 Mechanical response time 2 (For the reference) Full scale span voltage 1.5 Offset voltage 1.2 0.5 0.075 Full scale span voltage 1.2 2.0 0.075 Accuracy 1.2 5.0
Note ; 1) Please consult us available when you choose the C models. 2) Excluding input voltage error.
kPa kg/cm2 kPa VDC
VDC
RH mA mA mA msec V V V FS/0 50
1
Pre-amplified/3V Excitation/Gauge
Outline dimensions
X3PM,X3HM Data sheet
unit (mm)
X3PM
12 0.5 6 5 4 4 2.2 8
5 0.2
max 15
Pressure port 0.8 0.6 Vent hole
4.5 4 5 6
15.24(600mil)
R1.5 3 C0.5
14
1
2
3 Terminal leads
3
2
1
Labelled faceplate
6.8 2.8
Recommended footprint for PCB
6- 0.9(Diameter of through holes)
2.54 2.54
6- 1.8(Diameter of lands)
1.2
60
15.2
unit (mm)
unit (mm)
X3PM-R
0.2
12
max 15
4 0.5 2.2
8
5
6
5
4
0.8 Pressure port
4
5
6
R1.5 14 3
C0.5 1 2 3 Terminal leads Labelled faceplate 0.6 Vent hole 32 4.5 1
0.5
15.24(600mil)
2.54 2.54
Recommended footprint for PCB
6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands)
1.2
60
2.8 6.8
15.2
unit (mm)
2
2.54 2.54
2.54 2.54
0.5
Pre-amplified/3V Excitation/Gauge
Outline dimensions
X3PM,X3HM Data sheet
X3HM-R
1
2.54 2.54 2 3
unit (mm)
Pressure port
6
5
4
(14) 1.2
1
3.2
1.55 2.6 6 0.6 4.7
5.5
15
10.16
0.25
Vent hole
3.4 (7.6)
Labelled faceplate
8 6 5 4
Recommended footprint for PCB
6- 1(Diameter of through holes) 6- 1.8(Diameter of lands)
8
1
2
3
10
unit (mm)
3
2.54 2.54
1
Pre-amplified/3V Excitation/Gauge
Connection diagram
X3PM,X3HM Data sheet
X3PM, X3HM
Vcc
Vcc(DC5V)
Vout Vout GND C2 C1
Remarks :
1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other.
GND
Transfer Function
Vout=Vs (P Vs=3.0volts
+ ) (Pressure Error Temperature Error Multiplier
Vs)
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
P=Input Pressure(kPa)
Model 050KPG(D) 100KPG(D) 100KPGV(DV) 100KPGW(DW) 200KPG(D) 001MPG(D) 115KPA pressure range 0 50kPa 0 100kPa 0 100kPa 100 +100kPa 0 200kPa 0 1MPa 15 115kPa.abs 0.01 0.005 0.005 0.0025 0.0025 0.0005 0.005 0.1667 0.1667 0.1667 0.4167 0.1667 0.1667 0.09167 Pressure Error(kPa) 2.5 5.0 5.0 10.0 10.0 50.0 5.0
Temperature Error Multiplier=1
Note ; Please read instruction "Notes" before using the sensor. Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 4 E-mail : sensor@fujikura.co.jp


▲Up To Search▲   

 
Price & Availability of X3PM-100KPGVR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]